ASTM D611 Petroleum Aniline Point Tester
ASTM D611 Petroleum Aniline Point Tester
MT-AP907
The Automatic Aniline Point Tester is designed to determine the aniline point of petroleum products and hydrocarbon solvents. The instrument complies with ASTM D611 and GB/T 262 – Standard Test Method for Aniline Point and Mixed Aniline Point of Petroleum Products and Hydrocarbon Solvents.
Introduction
The aniline point is defined as the minimum temperature at which equal volumes of aniline and petroleum sample are completely miscible. It is widely used as an indicator of the aromatic hydrocarbon content in petroleum products. Oils with lower aniline points generally contain higher aromatic content, while higher aniline points indicate higher paraffinic content.
This fully automatic Aniline Point Tester integrates microprocessor temperature control, optical detection technology, and intelligent cloud-point recognition, enabling accurate determination of the turbidity point during the aniline point test. The instrument supports testing of both transparent and opaque samples, providing reliable results for petroleum laboratories.
With automated detection, data storage, and advanced temperature control, the instrument offers high precision, stable operation, and efficient laboratory testing for petroleum product analysis.
Typical Applications
The ASTM D611 Aniline Point Tester is used for determining the aniline point of petroleum products and hydrocarbon solvents.
- Diesel fuel
- Jet fuel
- Lubricating oils
- Hydrocarbon solvents
- Petroleum distillates
- Mineral oils
Typical application environments include:
- Petroleum refineries
- Lubricant manufacturing plants
- Fuel quality control laboratories
- Petrochemical research institutes
- Inspection and certification laboratories
Key Features
1. Intelligent Microprocessor Control
The instrument adopts an STM microprocessor control system with adaptive PD temperature control algorithm, automatically adjusting the heating curve according to the requirements of the testing standard.
2. Automatic Turbidity Detection
The system automatically detects the appearance of turbidity during heating, accurately determining the aniline point and automatically generating test results.
3. Non-Contact Infrared Detection
A non-contact infrared detection system monitors the entire testing unit, ensuring reliable and precise measurement.
4. Suitable for Transparent and Opaque Samples
The instrument can measure both transparent and opaque samples, providing high-precision turbidity recognition.
5. External Cooling Bath Support
An optional external circulating cooling bath allows testing of petroleum products requiring lower temperature aniline point measurements.
6. Automatic System Error Correction
A differential detection system automatically corrects system deviation, and the instrument stops the test and issues an alarm when temperature limits are exceeded.
7. Large Data Storage Capacity
The analyzer can store up to 10,000 test records, enabling convenient data retrieval and historical analysis.
8. Data Export and Report Management
est data can be exported via USB drive and transferred to MS Excel or laboratory management systems (LMS).
9. Multi-Language Operation Interface
The instrument supports multiple language display options, and the software can be upgraded when testing standards are updated.
Technical Specifications
|
Name 4134_55d893-f5> |
MT-AP907 ASTM D611 Petroleum Aniline Point Tester 4134_603e16-70> |
|
Display 4134_62b4e2-03> |
Color Touchscreen 4134_0e7181-f5> |
|
Temperature Range 4134_3f5395-a7> |
Room Temperature – 160°C 4134_c1d0ab-62> |
|
Temperature Sensor 4134_146fbe-0d> |
PT100 4134_b64182-11> |
|
Detection Method 4134_3b10f8-86> |
Photoelectric Detection Unit 4134_466069-4a> |
|
Operating Environment 4134_7d1a81-c5> |
Temperature: 25°C ±10°C Relative Humidity: < 85% RH 4134_b231f2-9d> |
|
Pressure Chamber 4134_8c4814-b9> |
282 × 335 × 587 mm 4134_835ff7-e2> |
|
Maximum Vacuum 4134_9f777b-76> |
Approximately 18 kg 4134_c9139b-e7> |
|
Power Supply 4134_e38336-8a> |
220 V ±10%, 50 Hz ±1 Hz 4134_35e891-ff> |
Standards Compliance
The Automatic Aniline Point Tester complies with the following testing standards:
- ASTM D611 – Standard Test Method for Aniline Point and Mixed Aniline Point of Petroleum Products and Hydrocarbon Solvents
- GB/T 262 – Determination of Aniline Point and Mixed Aniline Point of Petroleum Products and Hydrocarbon Solvents
These standards are widely used for evaluating aromatic content and compatibility characteristics of petroleum products.
Why Choose Our Automatic Aniline Point Tester
Accurate Aromatic Content Evaluation
Provides reliable measurement of the aniline point for petroleum products and hydrocarbon solvents.
Fully Automated Testing
Automatic turbidity detection and temperature control ensure accurate and repeatable test results.
High-Precision Optical Detection
Non-contact infrared detection and photoelectric sensors enable precise identification of turbidity points.
Intelligent Data Management
Large internal storage and USB data export simplify laboratory data management.
Ideal for Petroleum Testing Laboratories
Widely used in petroleum refineries, fuel testing laboratories, lubricant manufacturers, and research institutes.