Automatic Closed Cup Flash Point Tester
Automatic Closed Cup Flash Point Tester
MT-FP101
The Automatic Closed Cup Flash Point Tester is a dedicated instrument for precise flash point determination using the Pensky-Martens Closed Cup method. It meets ASTM D93 and ISO 2719 standard.
Introduction
The Automatic Closed Cup Flash Point Tester is a dedicated instrument for precise flash point determination using the Pensky-Martens Closed Cup method.
Under controlled heating conditions, petroleum products release vapor that mixes with air inside a sealed cup. The lowest temperature at which this vapor ignites when exposed to an ignition source is defined as the flash point.
This model is specifically engineered for laboratories that require accurate and compliant closed cup flash point testing, without the complexity of dual-mode systems.
It is ideal for petroleum, chemical, power generation, and industrial quality control laboratories focused on ASTM D93 applications.
Typical Applications
The Automatic Closed Cup Flash Point Tester is suitable for:
- Lubricating oils
- Fuel oils and diesel
- Hydraulic oils
- Transformer oils
- Chemical solvents requiring closed cup testing
- Chemical liquids
Widely used in:
- Oil refinieries
- Lubricant production plants
- Power utilities
- Quality inspection laboratories
- Research facilities
Key Features
1. Dedicated ASTM D93 Heating Profile
The instrument is optimized for Pensky-Martens closed cup methodology with an adaptive PID-controlled heating curve that strictly follows ASTM D93 and ISO 2719 requirements.
2. Integrated Atmospheric Pressure Correction
An internal barometric pressure sensor continuously measures ambient pressure and automatically compensates flash point results for improved accuracy.
3. High-Sensitivity Flash Detection
Differential thermocouple detection ensures reliable flash recognition and minimizes false triggering or missed ignition events.
4. Fully Automated Closed Cup Operation
The entire closed cup test cycle—including stirring, ignition, detection, cooling, and result printing—is completed automatically.
5. Compact & Energy-Efficient Design
With a power consumption below 550W and a compact footprint (450 × 280 × 290 mm), this model is ideal for laboratories requiring space-efficient flash point testing equipment.
6. Safe Gas-Free Ignition System
Platinum alloy electric ignition eliminates the need for external gas supply, enhancing laboratory safety and simplifying installation.
7. Intelligent Self-Diagnosis System
The instrument features automatic fault detection and operational self-check functions to ensure reliable daily operation.
8. Large-Capacity Data Storage
Stores up to 10,000 test records with optional 500GB expansion for long-term data archiving.
Technical Specifications
|
Name 3921_fb2e22-fa> |
MT-FP101 Automatic Closed Cup Flash Point Tester 3921_93b93c-31> |
|
Display 3921_21ec9e-b2> |
Color Chinese-English touchscreen 3921_c13f6e-17> |
|
Measurement Method 3921_724133-cf> |
Differential thermocouple detection 3921_2d1af5-10> |
|
Measurement Range 3921_446597-0f> |
Room temperature – 400°C 3921_9ce849-16> |
|
Resolution 3921_2dda3a-a9> |
0.1°C 3921_0cb5b4-41> |
|
Repeatability 3921_c1d9d8-1f> |
<104°C: ±1°C / ≥104°C: ±2°C 3921_f10272-27> |
|
Cooling Method 3921_ddf024-eb> |
Forced air cooling 3921_5278cd-38> |
|
Ignition Method 3921_efee56-bf> |
Gas-free electronic ignition 3921_a84740-73> |
|
Temperature Sensor 3921_6053fd-10> |
Pt100 platinum resistance 3921_2cbbb1-68> |
|
Self-Diagnosis 3921_456cdd-0e> |
Automatic system fault detection 3921_2f3600-7c> |
|
Working Environment 3921_69f738-5c> |
10–45°C, 30–80% RH 3921_42db96-2d> |
|
Power Consumption 3921_a5e97a-c4> |
<550 W 3921_5f15ff-83> |
|
Dimensions (W × D × H) 3921_6f95c1-a0> |
450 × 280 × 290 mm 3921_1d2c68-b2> |
|
Power Supply 3921_020ca5-8e> |
AC 220 V ±10%, 50 Hz ±2.5 Hz 3921_6c847b-92> |
|
Weight 3921_a0249d-a9> |
15 kg 3921_a71147-8d> |
Standards Compliance
This Closed Cup Flash Point Tester complies with international and national standards including:
- GB 261, GB 21615, SH/T 0315
- ASTM D93 – Pensky-Martens Closed Cup Method
- ISO 2719
Specifically designed for closed cup flash point determination of petroleum products.
Why Choose Our Automatic Closed Cup Flash Point Tester
Specialized for Closed Cup Accuracy
Purpose-built for Pensky-Martens testing, ensuring focused performance without unnecessary dual-mode complexity.
Reliable and Repeatable Results
Precise heating control and high-sensitivity detection guarantee consistent flash point determination.
Space-Saving Laboratory Solution
Compact structure suitable for laboratories with limited bench space.
Energy Efficient Operation
Lower power consumption compared to larger combined systems.
Safe & Gas-Free Ignition
Gas-free ignition and intelligent self-diagnosis reduce operational risk and maintenance workload.
Ideal for Routine Industrial Testing
A practical and cost-effective solution for daily ASTM D93 flash point analysis.