Karl Fischer Coulometric Trace Moisture Analyzer

MT-MC806

Karl Fischer Coulometric Titration Method for water content analysis in liquid, solid, and gaseous samples, covering a range from 0.0001% (1 ppm) to 100%.

Get a quote

Introduction

Our Karl Fischer Coulometric Trace Moisture Analyzer adopts the classic moisture measurement method, the Karl Fischer Coulometric Titration, and can quickly analyze moisture content in liquid, solid, and gas samples within a range of 0.0001% (1ppm) to 100% in just one minute. It can automatically calculate the percentage, ppm mg/L values of moisture content, as well as automatically replace reagents, requiring no manual operation.

Test Principle

Our trace moisture analyzers operate on the Karl Fischer coulometric/volumetric titration method, where iodine reacts quantitatively with water in the presence of sulfur dioxide and a suitable solvent. The amount of iodine consumed is directly proportional to the water content of the sample, enabling accurate moisture determination.

Typical Applications

  • Insulating oil and transformer oil
  • Lubricating oils and hydraulic oils
  • Fuels (diesel, gasoline, kerosene)
  • Crude oil and petroleum products
  • Chemical solvents and reagents
  • Pharmaceuticals and raw materials

Key Features

1. Intelligent Microprocessor Control

This trace moisture analyzer is controlled by an STM microprocessor for precise and automated moisture determination.

2. Large Color Touchscreen Interface

65K color touchscreen (800×600 resolution) displays real-time status and results with intuitive operation.

3. Fully Automated Reagent Handling

Automatic reagent injection and waste disposal prevent operator contact with chemicals.

4. Corrosion-Resistant, Easy-to-Clean Surface

The exterior surface is treated with electrostatic spraying for corrosion resistance and easy cleaning.

5. Automatic Blank Current Compensation

The blank current is automatically compensated by the microprocessor, allowing the reagent to quickly reach a balanced state.

6. High Sensitivity and Fast Analysis

A 430 mA large electrolysis current ensures high detection sensitivity and fast analysis speed.

7. Automatic Data Storage

Measurement results are automatically stored (up to 500 records), and historical data can be accessed at any time.

8. Comprehensive Report Generation

Automatically calculates and prints results, including ug, ppm, percentage content, mg/L, sample name, experiment date, and more.

9. USB/RS232 Connectivity

Supports USB or RS232 interfaces for communication with laptops or computers, enabling network management.

10. Multi-language Display and Upgradeable Program

Multiple language options for operation display, and the instrument’s program can be upgraded when national standards are revised.

Technical Specifications

Name

MT-WC806 Karl Fischer Coulometric Trace Moisture Analyzer

Display

65K 10-inch English color touchscreen (Resolution: 800×600 pixels)

Measurement Method

Microprocessor-controlled Karl Fischer volumetric titration

Electrolysis Speed

2.4 mg of water per minute

Electrolysis Current

0-430 mA, automatic control

Measurement Range

0.01 µg water to 200 mg water

Moisture Content Range

0.0001% (10 ppm) – 100%

Sensitivity

0.01 µg of water

System Accuracy

For water content between 10 µg and 1000 µg, the error is ≤ ±3 µg; for water content above 1000 µg, the error is ≤ ±0.2% (excluding sample injection error)

Drift Compensation

Automatic drift compensation controlled by microprocessor

Stirring Speed

Adjustable stirring speed control

Endpoint Indication

Screen display / Print output / Sound alarm / End-point light indication

Data Input

Touchscreen input operation

Sample Number

User-defined

Storage Function

500 records

Printer

Low-power, high-speed thermal printer, 56 mm paper width

Print Content

µg / Percentage content / ppm / mg/L / Sample number / Operator / Date

Calendar/Clock

Analysis time and date display, with printed output

Self-Diagnosis Function

Automatic instrument fault detection and diagnosis

Special Function

Can be connected to a laptop or other computers for online operation, or can function independently

Power Consumption

Less than 40 W

Dimensions (W × D × H)

390 × 300 × 170mm

Operating Conditions

Temperature: 5°C – 40°C, Humidity: < 85% RH

Power Supply

AC 220 V ±10%, 50 Hz ±2.5 Hz

Weight

7.3 kg

Applicable Standards / Compliance Standards

Karl Fischer Coulometric Method for Water Content Determination

1. General Chemical Products
  • GB/T 6283-2008 – Determination of Water Content in Chemical Products — Karl Fischer Method
  • ASTM E1064-2008 – Standard Test Method for Water Content of Organic Liquids by Coulometric Karl Fischer Titration
2. Petroleum, Crude Oil & Lubricant
  • ASTM D4928-00 (2010) – Standard Test Method for Water Content of Crude Oils by Coulometric Karl Fischer Titration
  • ASTM D6304-2007 – Standard Test Method for Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration
  • ISO 10337:1997 – Crude Petroleum — Determination of Water — Coulometric Karl Fischer Titration Method
  • GB/T 11146-2009 – Crude Oil — Determination of Water Content — Karl Fischer Coulometric Method
  • SH/T 0246-1992 – Test Method for Water Content in Light Petroleum Products (Coulometric Method)
  • SH/T 0255-1992 – Test Method for Water Content in Additives and Lubricating Oils Containing Additives (Coulometric Method)
3. Transformer Oil & Electrical Insulating Oils
  • GB/T 7600-1987 – Determination of Water Content in In-service Transformer Oil — Coulometric Method
4. Industrial Gases & Petrochemical Products
  • GB/T 3727-2003 – Determination of Trace Water in Industrial Ethylene and Propylene
  • GB/T 6023-2008 – Determination of Trace Water in Industrial Butadiene — Karl Fischer Coulometric Method
  • GB/T 7376-2008 – Determination of Trace Water in Industrial Fluorinated Alkanes — Karl Fischer Method
  • GB/T 18619.1-2002 – Natural Gas — Determination of Water Content — Karl Fischer Coulometric Method
  • GB/T 18826-2002 – Industrial 1,1,1,2-Tetrafluoroethane (HFC-134a)
5. Coking & Coal Chemical Products
  • GB/T 5074-1985 – Micro-coulometric Determination of Water Content in Coking Products

Why Choose Our Trace Moisture Analyzer

1. Proven Karl Fischer Technology

Based on the Karl Fischer coulometric titration method, ensuring accurate and reliable trace moisture determination.

2. Designed for Trace-Level Analysis

Measures water content from 1 ppm (0.0001%) to 100%, ideal for insulating oil and petroleum products.

3. Fast and Fully Automated Operation

Typical analysis completed within one minute with automatic reagent handling and result calculation.

4. User-Friendly Touchscreen Interface

65K color touchscreen (800 × 600 resolution) for clear display and easy operation.

5. Safe and Durable Design

Automatic reagent replacement reduces operator exposure; corrosion-resistant housing ensures long service life.

6. Data Storage and Connectivity

Stores up to 500 results and supports USB and RS232 communication.

FAQ – Trace Moisture Analyzer