Introduction
The MT-MC805 Karl Fischer Moisture Tester is designed for high-precision determination of water content across a wide range of applications. Utilizing Karl Fischer coulometric technology, the instrument enables rapid moisture analysis in liquid, solid, and gas samples, covering trace to high moisture levels from 1 ppm (0.0001%) up to 100%.
Fully automated measurement, result calculation, and reagent management significantly reduce operator involvement while ensuring consistent and reliable testing performance.
Test Principle
This Karl Fischer moisture tester is based on the coulometric titration principle, in which iodine is generated electrochemically and reacts stoichiometrically with water in the sample. The total electrical charge required to generate the iodine corresponds directly to the amount of water present. By precisely measuring this charge, the analyzer determines the moisture content with high accuracy and excellent repeatability.
Typical Applications
- Insulating oil and transformer oil
- Lubricating oils and hydraulic oils
- Fuels (diesel, gasoline, kerosene)
- Crude oil and petroleum products
- Chemical solvents and reagents
- Pharmaceuticals and raw materials
Key Features
1. Intelligent Microprocessor Control
This Karl Fischer moisture tester is controlled by an STM microprocessor, enabling intelligent and automatic moisture determination with high accuracy.
2. Large Color Touchscreen Interface
Equipped with a 10-inch 65K color touchscreen LCD with a resolution of 800 × 600 pixels.
3. Fully Automated Reagent Handling
Automatic reagent injection and waste discharge prevent operator contact with chemicals, improving safety and ease of use.
4. Corrosion-Resistant, Easy-to-Clean Surface
The housing is treated with electrostatic spray coating for excellent corrosion resistance and easy cleaning.
5. Optional Electronic Balance Connectivity
Supports optional connection to an electronic balance for data communication and integrated sample mass processing.
6. Automatic Blank Current Compensation
The microprocessor automatically compensates blank current, allowing the reagent to reach equilibrium quickly.
7. High Electrolysis Current for Fast Analysis
Electrolysis current adjustable from 0 to 430 mA, ensuring high sensitivity and rapid moisture analysis.
8. Large Data Storage Capacity
Automatically stores up to 1,000 test results, allowing convenient access to historical data.
9. Automatic Measurement and Averaging
Sample measurement and result display are fully automatic, with support for calculating average values from multiple tests.
10. Comprehensive Result Calculation and Printing
Automatically calculates and prints results in µg, ppm, %, mg/L, along with sample name and test date.
11. USB Connectivity and Multi-Language Support
USB interface enables connection to computers for data management, with multi-language operation and upgradeable software.
Technical Specifications
|
Name 3828_4d97f2-59> |
MT-WC805 Fully Automatic Karl Fischer Moisture Tester 3828_a0c23e-f0> |
|
Display 3828_c7b5cf-1a> |
65K 10-inch English color touchscreen (Resolution: 800×600 pixels) 3828_a681ca-30> |
|
Measurement Method 3828_c3b1f8-24> |
Microprocessor-controlled Karl Fischer volumetric titration 3828_6962a7-19> |
|
Electrolysis Speed 3828_27f4ae-ff> |
2.4 mg of water per minute 3828_274489-6e> |
|
Electrolysis Current 3828_48ac14-07> |
0-430 mA, automatic control 3828_29a35a-8f> |
|
Measurement Range 3828_5fc886-e7> |
0.01 µg water to 200 mg water 3828_c099e0-55> |
|
Moisture Content Range 3828_47b606-98> |
0.0001% (10 ppm) – 100% 3828_0fd2dd-00> |
|
Sensitivity 3828_75d307-ae> |
0.01 µg of water 3828_459fce-bd> |
|
System Accuracy 3828_19b7b8-15> |
For water content between 100 µg and 1000 µg, the error is ≤ ±3 µg; for water content above 1000 µg, the error is ≤ ±0.2% (excluding sample injection error) 3828_9eb60a-41> |
|
Drift Compensation 3828_bde1e6-7e> |
Automatic drift compensation controlled by microprocessor 3828_1380d0-d5> |
|
Stirring Speed 3828_4adc5a-92> |
Adjustable stirring speed control 3828_1ee7b1-e3> |
|
Endpoint Indication 3828_054182-2b> |
Screen display / Print output / Sound alarm / End-point light indication 3828_966c52-16> |
|
Data Input 3828_7affd1-c2> |
Touchscreen input operation 3828_a77948-e8> |
|
Sample Number 3828_2d5bd1-47> |
User-defined 3828_b9533e-79> |
|
Storage Function 3828_5377d3-80> |
1000 records 3828_76d2a1-8d> |
|
Printer 3828_b03a97-c4> |
Low-power, high-speed thermal printer, 56 mm paper width 3828_8e48f7-a3> |
|
Print Content 3828_b4c3d8-ed> |
µg / Percentage content / ppm / mg/L / Sample number / Operator / Date 3828_93da8a-2b> |
|
Calendar/Clock 3828_7daa84-53> |
Analysis time and date display, with printed output 3828_354af4-87> |
|
Self-Diagnosis Function 3828_8ae8b3-cc> |
Automatic instrument fault detection and diagnosis 3828_618aa5-27> |
|
Special Function 3828_3f24ac-3f> |
Can be connected to a laptop or other computers for online operation, or can function independently 3828_2a3e2e-b9> |
|
Power Consumption 3828_1dd1db-ee> |
Less than 40 W 3828_297504-40> |
|
Dimensions (W × D × H) 3828_d7e9c2-74> |
390 × 300 × 170mm 3828_2561f1-53> |
|
Operating Conditions 3828_9c963a-89> |
Temperature: 5°C – 40°C, Humidity: < 85% RH 3828_b17fbc-e7> |
|
Power Supply 3828_a82dc3-46> |
AC 220 V ±10%, 50 Hz ±2.5 Hz 3828_7d9ef0-d7> |
|
Weight 3828_b7b046-6a> |
6 kg 3828_efa3d3-4e> |
Applicable Standards / Compliance Standards
Karl Fischer Coulometric Method for Water Content Determination
- ASTM D4928-00 (2010) – Standard Test Method for Water Content of Crude Oils by Coulometric Karl Fischer Titration
- ASTM D6304-2007 – Standard Test Method for Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration
- ISO 10337:1997 – Crude Petroleum — Determination of Water — Coulometric Karl Fischer Titration Method
- ASTM E1064-2008 – Standard Test Method for Water Content of Organic Liquids by Coulometric Karl Fischer Titration
- SH/T 0246-1992 – Test Method for Water Content in Light Petroleum Products (Coulometric Method)
- SH/T 0255-1992 – Test Method for Water Content in Additives and Lubricating Oils Containing Additives (Coulometric Method)
- GB/T 7600-1987 – Determination of Water Content in In-service Transformer Oil — Coulometric Method
- GB/T 3727-2003 – Determination of Trace Water in Industrial Ethylene and Propylene
- GB/T 6023-2008 – Determination of Trace Water in Industrial Butadiene — Karl Fischer Coulometric Method
- GB/T 6023-2008 – Determination of Trace Water in Industrial Butadiene — Karl Fischer Coulometric Method
- GB/T 18619.1-2002 – Natural Gas — Determination of Water Content — Karl Fischer Coulometric Method
Why Choose Our Karl Fischer Moisture Tester
1. Designed for Accurate Karl Fischer Moisture Analysis
Our Karl Fischer moisture testers are built on proven coulometric technology and optimized for trace-level water determination. With a wide measurement range and high electrolysis current, the instrument delivers fast, stable, and repeatable results for demanding applications.
2. Fully Automated Operation for Consistent Results
From reagent injection and blank current compensation to result calculation and data storage, the entire testing process is fully automated. This minimizes operator influence and ensures consistent performance across routine laboratory and industrial testing.
3. Intelligent Control and User-Friendly Interface
An STM microprocessor combined with a large color touchscreen enables intuitive operation, real-time status monitoring, and efficient workflow, even for extended daily use.
4. Enhanced Safety and Durable Construction
Automatic reagent handling reduces operator exposure to chemicals, while the corrosion-resistant electrostatic coating ensures long-term reliability in harsh laboratory and industrial environments.
5. Flexible Data Management and System Integration
With large internal storage and USB connectivity, test data can be easily reviewed, transferred, and integrated into laboratory or quality management systems. Optional electronic balance connectivity further improves data integrity.
6. Reliable Solution for Laboratory and Industrial Applications
Designed for continuous operation, these Karl Fischer moisture testers are suitable for laboratories, power utilities, petrochemical facilities, and quality control environments where accurate moisture measurement is critical.